WICTEC 50 FP / WICTEC 60 FP
WICTEC 50 FP and WICTEC 60 FP fire protection curtain wall provides performance when needed in areas such as stairwells, extensions, hallways and glazed roofs, in accordance with classifications G30 / F30 (DIN) and EI 30 / EI 60 (EN). All architectural concepts of WICTEC 50 and WICTEC 60 can be realised and adapted to provide the necessary fire protection requirements, as well as being seamlessly integrated into standard façades where fire protection is not required.
Documentation
Characteristics
System test results / CE product pass in accordance with DIN EN 13830
Air permeability
Water tightness
Resistance to wind load
Impact resistance
Approval
Quality assurance
Environmental management
Class AE
RE 1200
2000 / –3200,
safety 3000 / –4800 Pa
Class E5 / I5
German approval: For vertical curtain wall and overhead glazing in accordance with F30 and G30
Certified according to ISO 9001:2008
Certified according to ISO 14001
Approval in accordance with national regulations.
Technical performance
System width
Basic system
Fire protection classes
Infill dimensions
Heigth of façade
Polygon façade
Infill thickness
50 mm / 60 mm
WICTEC 50 / WICTEC 60
G30 / F30 (DIN) EI 30 / EI 60 (EN)
Portrait format up to 1800 mm x 3000 mm Landscape format up to 2400 mm x 1400 mm
up to 5000 mm
up to ± 5°
F30 / G30: up to 38 mm, EI 30 / EI 60: up to 57 mm
System technology
- For vertical and overhead glazing (fire protection up to 0º inclination)
- Slim sight lines: 50 mm or 60 mm
- Compatible and structurally identical with WICTEC 50 and WICTEC 60 standard systems
- Infills: glass or panel
- Extended freedom in design with large infill dimensions possible
- Suitable for internal and external applications
- The WICONA fire protection parapet, in resistance class W90, offers the appropriate solution to prevent fire flashover with standard façades.
- Can also be combined with WICSTYLE 77 FP fire protection doors and WICLINE 75 FP fire protection windows